The BIX-H4T is an advanced intramuscular injection model built around a half-pelvis with the proximal femur, greater trochanter, anterior and posterior superior iliac spines and sacrum moulded in. A removable left buttock quadrant exposes the gluteus medius, gluteus maximus, sciatic nerve and vessels, and the model supports three injection routes.
Quick answer. The H4T is the anatomy-first gluteal trainer: it teaches why a site is safe by letting students look under the skin before they inject. It has no electronic feedback and no fluid reservoir, so it is a teaching and technique model, not an assessment simulator. Buy it for landmark teaching; pair it with an electronic simulator if you also need scored practice.
| Item | Specification | Teaching consequence |
|---|---|---|
| Bony landmarks | Proximal femur, greater trochanter, ASIS, PSIS, sacrum | Students palpate the same points used clinically |
| Removable quadrant | Left buttock, one quarter | Nerve and muscle relationships become visible |
| Exposed structures | Gluteus medius, gluteus maximus, sciatic nerve, vessels | Explains why the ventrogluteal site is preferred |
| Routes | Dorsogluteal, ventrogluteal, vastus lateralis | Three techniques on one model |
| Material | Imported plastic elastomer, high-temperature sintered mould | Needle tracks close; surface resists repeated puncture |
| Documentation | BIX-H4T.pdf datasheet | Specification can be filed with a tender |
Students are taught to avoid the sciatic nerve, but on a closed model the nerve is invisible. The H4T removes one quadrant of the left buttock so the class can see the nerve lying deep to the gluteus maximus, then replace the quadrant and inject into the same area.
That sequence answers the question students actually ask — "how do I know I am not near the nerve?" — with anatomy rather than a rule. Sciatic nerve injury from gluteal injection remains a reported complication, which is why the ventrogluteal site is recommended in nursing guidance.[1][2]
Practising all three on one model prevents the common error of treating "gluteal injection" as a single technique.
Buy the H4T if the priority is teaching landmarks and safe zones, especially in a programme that has limited anatomy lab time. Do not buy it as the only injection trainer if your assessments require objective pass/fail results; add an electronic buttocks simulator for that purpose.
Q1. What does the removable quadrant show? The left buttock quarter lifts off to expose the gluteus medius, gluteus maximus, sciatic nerve and vascular structures.
Q2. Which injection routes are supported? Dorsogluteal, ventrogluteal and vastus lateralis injection.
Q3. Does it give electronic feedback? No. The model is mechanical; assessment is by instructor observation.
Q4. What material is it made of? An imported plastic elastomer, injection-moulded in a stainless-steel mould and sintered at high temperature.
Q5. Can it be used for paediatric injection training? No. It is an adult half-pelvis model.
Q6. What is the price? Price is quoted per order; request the model plus spare-quadrant price together.
Contact. For the BIX-H4T datasheet, spare quadrant pricing or a programme quotation, email adanursing@adaanatomy.com. Product page: https://www.adanursing.com/nursing-model/advanced-intramuscular-injection-training-model-H4T · Nursing models: https://www.adanursing.com/nursing-model · All articles: https://www.adanursing.com/neslist.html