【 function】
▎Large-screen LCD display: artificial respiration and chest compressions, simulated heart beat display, simulated electrocardiogram display, huge chart data statistics display; simulated standard airway opening;
▎When artificial hand position chest compression:
1. The dynamic bar code indicator shows the pressing depth: the correct pressing depth (5-6cm area) is displayed by the green light of the bar code, the pressing depth is not enough (less than 5cm) is caused by the yellow bar code, and the pressing depth is too deep (more than 6cm) by the red bar code indicator. Dynamic feedback shows the depth of CPR compression.
2. LCD count display: It records in detail the number of correct and incorrect pressings (the number of times the pressing force is too large, the pressing force is too small, and the pressing position is wrong).
3. Huge graph data statistics: detailed graph statistics display such as correct pressing, excessive pressing force, insufficient pressing force, and incorrect pressing
4. Language prompts: Chinese voice prompts, with detailed information about the specific reasons for pressing errors, so that the trainer can correct them in time.
▎When breathing from artificial mouth (blowing):
1. The dynamic bar code indicator shows the tidal volume: the inhaled tidal volume (500/600ml-1000ml) is displayed by the bar code green light, the inhaled tidal volume is too small or too large, and the dynamic feedback moisture is moved by the yellow or red bar code indicator respectively. Amount
2. LCD count display: It records in detail the times of correct and incorrect blowing (the times of excessive tidal volume and low tidal volume).
3. Data statistics of huge graphs: detailed statistics of huge graphs such as excessive blowing power, insufficient blowing power, and correct blowing.
4. Language prompt: Chinese voice prompt, in detail the specific reason of the blowing error, so that the trainer can correct it in time.
▎The ratio of compression to artificial respiration: 30:2 (single or double).
▎Operation cycle: first 30 times of pressing and then 2 times of blowing 30:2 five cycle cycle CPR operation.
▎Operation frequency: 2020 International New Edition Cardiopulmonary Resuscitation Operation Standard: at least 100~1200 times/min.
▎Operation method: training operation; popular assessment, custom assessment.
▎Operation time: time in seconds.
▎Language setting: You can set the language prompt setting and prompt volume adjustment setting; or turn off the language prompt setting.
▎Score printing: The results of the operation can be thermally printed with long and short transcripts.
▎Check pupil response: before the assessment operation and after the completion of the assessment procedure, it simulates the true manifestation of the automatic dynamic change process of pupil dilation and shrinkage.
▎Check carotid artery response: touch and check by hand to simulate the automatic carotid artery pulsation response during the pressing operation; and the true manifestation of the carotid artery automatic pulsation response after the completion of the assessment procedure.
【 nursing functions】
▎ Wash hair and face;
▎Arm venous puncture, infusion (blood) injection;
▎ Deltoid muscle injection;
▎Extrafemoral muscle injection;
▎Enema method;
▎Male and female catheterization;
▎Bladder irrigation for men and women;
▎Overall care: scrub, wear and change clothes;
▎Bend, rotate, move up and down the limbs and joints。